NEWS   /  GUIDES

CIP Systems for Food and Beverage Plants: A Practical Guide

A plain guide to clean-in-place (CIP) for food and beverage plants: the cleaning cycle, choosing a system type, components, hygienic pipework and verification.

8 MIN READ

Welders at work on a steel vessel before weld inspection begins
In this article
  1. What does a CIP system do?
  2. A typical CIP cycle
  3. Types of CIP system
  4. Components of a CIP set
  5. Designing process pipework for CIP
  6. Verifying that CIP works
  7. Utilities a CIP system depends on
  8. Commissioning a CIP system
  9. Safety
  10. Common mistakes to avoid
  11. FAQ
  12. Talk to Maven about your CIP installation

In a food or beverage plant, cleaning is part of production. Tanks, pipelines, heat exchangers and fillers must be cleaned regularly and reliably, often every day, without taking the equipment apart. A clean-in-place (CIP) system does this by circulating water and cleaning chemicals through the process equipment in a controlled sequence. A well-designed CIP system protects product safety, saves water and chemicals, and gives production time back. A poor one wastes resources and may still leave soil behind.

This guide is for plant managers, quality managers and engineers in dairies, breweries, beverage plants, juice factories and food processors. It explains how CIP works, the main system types, what a CIP set contains and how process pipework must be designed for CIP to succeed.

What does a CIP system do?

A CIP system prepares cleaning solutions at the right concentration and temperature, pumps them through the process circuit at the right flow, returns them, and either reuses or discharges them. It does this in a defined sequence, controlled automatically, and records what happened.

Cleaning effectiveness depends on four factors working together, often described as time, mechanical action (turbulence or spray impact), chemistry (concentration) and temperature. If one is reduced, others must increase to compensate. That is why a CIP system has to control all four, not just dose chemicals.

A typical CIP cycle

The exact programme depends on the product and the soil, but a common sequence, as described in a CIP guide from A&B Process Systems (now part of JBT), looks like this:

  1. Initial drain of product from the equipment.
  2. Pre-rinse with water, often recovered from the previous final rinse, to flush out loose soil.
  3. Detergent wash, usually with a hot alkaline (caustic) solution, to remove fats, proteins and organic residues.
  4. Intermediate rinse to flush out the detergent.
  5. Acid wash where needed, to remove mineral deposits such as milkstone or beerstone.
  6. Final rinse with clean water.
  7. Sanitising step where required, using a chemical sanitiser, followed by a rinse if the sanitiser is not a no-rinse type.

The same guide notes that individual rinse and wash steps commonly last from about 5 minutes to an hour, and that wash temperatures are usually tightly controlled. Your chemical supplier and quality team should set the actual concentrations, temperatures and times for each circuit.

Types of CIP system

Type How it works Strengths Limitations
Single-use Solution made up for each clean, used once and discharged Low capital cost, small footprint, flexible, no cross-contamination between circuits Higher water, chemical, energy and effluent costs
Recovery (reuse) Detergent and rinse water stored in tanks and reused Saves water, chemicals and heat; common in dairy and food Larger footprint; one concentration and temperature unless more tanks added; must manage solution quality
Multi-tank Separate tanks for different water grades and solutions Flexible, controlled; preferred in high-hygiene sectors Higher capital cost and space
Decentralised / satellite Small CIP units close to the equipment they clean Short pipe runs, less hold-up, faster cycles More units to maintain

Many plants combine approaches, for example a central recovery CIP set for tanks and process lines and a separate single-use unit for a sensitive filler.

Choosing for Nigerian conditions

Water supply, effluent treatment capacity and energy cost all influence the choice. Plants that pay heavily to treat borehole water, heat solutions with diesel- or gas-fired boilers, or have limited effluent treatment capacity often find that recovery systems repay their extra cost. Plants with frequent product changes or allergen concerns may favour single-use circuits.

Components of a CIP set

  • Tanks for water, detergent, acid and recovered rinse, in stainless steel, with level sensors.
  • Supply pump sized for the flow and pressure needed by the largest circuit.
  • Heating by plate or shell-and-tube heat exchanger, or direct steam injection, with temperature control.
  • Chemical dosing pumps to make up and top up solution strength.
  • Return pumps or eductors, where gravity alone will not bring solution back from tanks.
  • Instrumentation: conductivity meters for concentration and to detect the interface between water and chemicals, temperature sensors, flow meters and level sensors.
  • Spray devices in tanks: static spray balls, rotating spray heads or rotary jet heads, selected for the tank size and soil.
  • Routing: valve arrays or swing-bend transfer panels that connect CIP to each circuit. A&B’s guide mentions proximity sensors on transfer panels to confirm correct connections.
  • Control system, usually PLC-based, running programmes and recording results.

Designing process pipework for CIP

The CIP set can only clean what the solution actually reaches at the right velocity. Most cleaning failures come from the process plant, not the CIP set. EHEDG, the European Hygienic Engineering and Design Group, has published a dedicated guideline on hygienic design requirements for CIP installations (Guideline 50), which is a useful reference for designers.

Velocity and turbulence

Cleaning solution must flow fast enough through pipes to create turbulence at the wall. A&B’s guide quotes process piping velocities of approximately 5 feet per second (about 1.5 m/s) for CIP, with higher velocities used in some pharmaceutical systems. This means the CIP supply pump must be sized for the largest-diameter line in each circuit, not just the average.

Dead legs

Branches off the main line where solution does not flow, such as instrument tees, capped connections and unused valve ports, collect soil and are hard to clean. Keep them as short as possible, or eliminate them.

Drainability

Pipework and equipment should drain by gravity, pitched towards drain points. Pools of water left in low points support microbial growth between cleans.

Split flows

Where a line splits into parallel branches, flow divides and velocity in each branch drops. A&B notes that split-flow designs reduce solution flow. Either clean branches in sequence or size the pump for the combined flow.

Hygienic components

  • Stainless steel pipe with smooth internal finish.
  • Orbital welds with full penetration and smooth internal beads, inspected.
  • Hygienic fittings and gaskets that do not leave crevices.
  • Valves designed for CIP, such as mix-proof valves where product and CIP lines cross.
  • Tank spray devices positioned so no area is in a shadow.

Good stainless process piping is a specialist skill. Poor welds with internal crevices or discoloured, oxidised surfaces are very hard to clean.

Verifying that CIP works

A CIP system should be able to demonstrate that it cleans effectively. A&B frames verification around three questions:

  1. Is the system working as intended (flows, temperatures, concentrations, times)?
  2. Is the required level of cleanliness achieved?
  3. Are cleaning chemicals fully removed?

Instrument records answer the first. Swab tests, rinse water analysis and microbiological testing answer the others. For tank spray coverage, a riboflavin test, in which the tank is coated with riboflavin solution and checked under UV light after rinsing, shows areas the spray device misses.

Records

Keep automatic records of every CIP run: circuit, programme, temperatures, concentrations, flows and times, with alarms for any step that fails. These records support food safety management systems and customer audits.

Utilities a CIP system depends on

A CIP set is only as reliable as the utilities feeding it. Plan these at the same time as the CIP design:

  • Water. Enough flow and storage for the largest circuit, at a quality agreed with the quality team. Hard or iron-rich borehole water can leave deposits and may need treatment before use in rinses.
  • Steam or hot water. Heating detergent to temperature quickly needs adequate steam capacity at the CIP heat exchanger, with a stable pressure supply and proper condensate drainage.
  • Compressed air. Clean, dry air for valve actuators on routing panels and tank outlets.
  • Power. Pumps and controls that ride through generator changeovers without leaving a circuit half cleaned, or that restart the step safely.
  • Effluent. Drains and treatment capacity for peak discharge, including pH neutralisation of spent caustic and acid.

Commissioning a CIP system

  1. Pressure test and flush all CIP supply and return pipework.
  2. Check every routing combination, and confirm interlocks prevent incorrect connections.
  3. Run each circuit with water first, measuring flow, velocity in the largest line, return and drain-down.
  4. Calibrate conductivity, temperature and flow instruments.
  5. Carry out riboflavin coverage tests on tanks.
  6. Introduce chemicals, confirm concentrations and temperatures, and set rinse end points from conductivity.
  7. Validate cleaning with swabs and microbiological tests before handing over.

Safety

CIP uses hot caustic and acid solutions. Design for operator safety:

  • Interlocks to prevent CIP starting on an incorrectly connected circuit.
  • Bunded chemical storage and safe delivery points.
  • Eye wash and safety showers near chemical areas.
  • Clear separation of product and CIP lines to prevent chemicals reaching product.

Common mistakes to avoid

  • Sizing the supply pump on average lines, so the largest line never reaches cleaning velocity.
  • Long dead legs at instrument tees and spare connections.
  • Undrainable pipework with sags between supports.
  • Choosing spray balls that do not cover the whole tank.
  • No conductivity measurement on return, so rinse endpoints are guessed.
  • Running CIP without records.

FAQ

What is the difference between CIP and COP?

CIP cleans equipment in place by circulating solutions. Clean-out-of-place (COP) means dismantling parts and cleaning them separately, for example in a wash tank.

Should we choose a single-use or recovery CIP system?

It depends on water, chemical and energy costs, effluent capacity, number of circuits and hygiene risk. Many plants use recovery systems for general process lines and single-use for sensitive equipment.

How fast should CIP solution flow?

Fast enough to create turbulence. A&B’s guide quotes about 1.5 m/s in process piping; your designer should confirm velocities for each line size.

How do we know a tank is being cleaned fully?

A riboflavin coverage test shows whether spray devices reach every surface. Swabs and microbiological tests confirm cleanliness.

Talk to Maven about your CIP installation

Maven Technical Services fabricates and installs stainless steel process piping, tanks and utilities for food and beverage plants. If you are planning a new CIP system, extending an existing one or tackling cleaning problems on your lines, speak to Maven’s engineers about hygienic pipework design and installation.

Planning work like this?

Send us the drawings, the scope or just the problem. We will come back with a method, a schedule and a price.

More updates

All news